Certified to
NSF/ANSI 44
NSF/ANSI/CAN 61 and 372
Compatible with the following typical concentrations of regenerants or chemicals
Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines
Made in The USA
Models & features
Specifications
General | |
Inlet/Outlet Fitting Connections | 3” Female NPT or BSPT |
Cycles | up to 9 |
Valve Material | Lead free brass |
Regeneration | Downflow |
Operating Pressures | 20 - 125 psi (1.4 - 8.6 bar) |
Operating Temperatures | 40º - 110º F (4º - 43º C) |
Options | Backwash Filter |
FLow rates | |
Service @15 psi drop |
250 gpm (946 lpm) (56.8 m3 /h) |
Backwash @25 psi drop |
220 gpm (833 lpm) (50.0 m3 /h) |
Cv Service | 64.6 |
Cv Backwash | 44.0 |
Tank applications | |
Water Softener | 18” - 63" diameter |
Water Filter | 18” - 48" diameter |
Meter |
Accuracy |
Flow Rate Range |
Gallon Range |
Totalizer |
Dimensions & Weight | |
Distributor Pilot | 18” - 48" diameter |
Drain Line | 3” Female NPT/BSPT "No Groove Lock" |
Brine Line |
1” Male NPT elbow ¾” x 1” solvent weld elbow |
Mounting Base | 6” Flange or Side Mount |
Height From Top Of Tank | 6" Flange QC Base - 12.5” (318mm) |
Weight | 57 lbs (25.9 Kg) |
Cycles of Operation Minutes |
|
Backwash 1st (upflow) | 1 - 95 |
Regenerate Draw/Slow Rinse (downflow) | 1-180 / 1-95 |
Backwash 2nd (upflow) | |
Fast Rinse (downflow) | 1-95 |
Regenerant Refill in service with treated water |
0.1 - 99 |
Service (downflow) | |
Hold (service) | 1 - 480 |
Electrical Specifications All models excluding WS1.25SD |
US power supply | International power supply |
Supply Voltage | 120VAC | 240VAC |
Supply Frequency | 60 Hz | 60 Hz |
Output Voltage | 24VDC | 24VDC |
Output Current | 800 mA | 800 mA |
Battery Specifications |
Battery |
Charging |